P o w e r u n i t T Z W N - 0 5
The device is part of a set dedicated to actively neutralize excessive electrostatic charges that are
created on the surface of processed materials.
It is dsigned to cooperate with pointed electrodes type JO96/x/L.
Its function is to provide high voltage needed to create ions around the points of electrodes.
The electrified material near the electrode attracts appropriate ions under the influence
of electrostatic forces, which neutralizes its charge.
The power supply is designed to operate under a voltage of 230Vac and frequency of 50Hz from mains supply.
Constructed as a single-step transistorized inverter with separate circuits controlling high-voltage windings.
The power supply provides voltage of about 7kV. In order to improve the efficiency
of the neutralization of the charges, the output voltage of increased frequency (about 1,2 kHz)
and specially modified waveform has been used. To ensure safety of use, output current is limited to 1mA.
Limited current capacity of high voltage source limits the length of usable electrode.
Electrode JO96/x/L of a usable length of not more than 2600mm can be connected to one TZWN-05 power unit.
If more than one electrode is in use, the total usable length of all the electrodes should also not
exceed 2600mm.
Ground connector of TZWN-05 power supply and aluminium body of JO96/x/L electrode should be connected
to the earthed machine frame.
High voltage cable connecting the power supply with the electrode should be relatively short
(we recommend placing in insulating tubes).
Rated data
- type ...................................................................... TZWN-05
- compatible item ....................................................... electrodes JO96/x/L
- supply voltage .......................................................... 230V, 50Hz
- input power ............................................................. 12 VA
- output voltage (with electrode JO-96/1800
with cable length 1500mm applied) ................................. 7 kV - output short-circuit current ........................................... < 1 mA
- output voltage frequency .............................................. 1,2 kHz
- maximum combined usable length of electrodes .................. 2600 mm
- recommended combined usable length of electrodes ............ < 2000 mm
- number of high voltage connections ................................. 2
(cascading of electrodes is recommended, number of electrodes is not limited) - operation mode ......................................................... continous
- dimensions: length (with glands) x width x height. ............... 200(230)x160x94 mm